Thermal performance optimization of the underground power cable system by using a modified Jaya algorithm
Authors:
- Paweł Ocłoń,
- Piotr Cisek,
- Monika Rerak,
- Dawid Taler,
- R. Venkata Rao,
- Andrea Vallati,
- Marcin Pilarczyk
Abstract
This paper presents a modified Jaya algorithm for optimizing the material costs and electric-thermal performance of an Underground Power Cable System (UPCS). A High Voltage (HV) underground cable line with three 400 kV AC cables arranged in flat formation in an exemplary case study is considered. When buried underground, three XLPE high voltage cables are situated in thermal backfill layer for ensuring the optimal thermal performance of the cable system. The study discusses the effect of thermal conductivities of soil and cable backfill material on the UPCS total investment costs. The soil thermal conductivity is assumed constant and equal to 0.8 W/(m K). The cable backfills considered in the study are as follows: sand and cement mix, Fluidized Thermal Backfill™ (FTB) and Powercrete™ a product of Heidelberg Cement Group. Constant thermal conductivities of the backfills in the dry state are assumed, respectively, 1.0 W/(m K), 1.54 W/(m K) and 3.0 W/(m K). The cable backfill dimensions and cable conductor area are selected as design variables in the optimization problem. The modified JAYA algorithm is applied to minimize material costs of UPCS under the constraint that the cable conductor temperature shall not exceed its optimum value of 65C. The cable temperature is determined from the two-dimensional steady state heat conduction equation discretized using the Finite Element Method (FEM). The performance of the modified Jaya algorithm was compared with classical Jaya and PSO algorithms. The modified Jaya algorithm, for the presented case study, allows one to obtain lower values of the cost function.
- Record ID
- CUTda394cfd1e36455bbc7c9a6d4de662c3
- Publication categories
- ;
- Author
- Journal series
- International Journal of Thermal Sciences, ISSN 1290-0729, e-ISSN 1778-4166
- Issue year
- 2018
- Vol
- 123
- Pages
- 162-180
- Other elements of collation
- schem.; tab.; wykr.; Bibliografia (na s.) - 179-180; Bibliografia (liczba pozycji) - 50; Oznaczenie streszczenia - Abstr.; Data udostępnienia on-line - 2017-10-07; Numeracja w czasopiśmie - Vol. 123
- Keywords in English
- high voltage, underground power cable system, thermal backfill, Jaya algorithm, finite element method
- DOI
- DOI:10.1016/j.ijthermalsci.2017.09.015 Opening in a new tab
- URL
- http://www.sciencedirect.com/science/article/pii/S129007291631331X Opening in a new tab
- Language
- eng (en) English
- Score (nominal)
- 45
- Additional fields
- Indeksowana w: Web of Science, Scopus
- Uniform Resource Identifier
- https://cris.pk.edu.pl/info/article/CUTda394cfd1e36455bbc7c9a6d4de662c3/
- URN
urn:pkr-prod:CUTda394cfd1e36455bbc7c9a6d4de662c3
* presented citation count is obtained through Internet information analysis, and it is close to the number calculated by the Publish or PerishOpening in a new tab system.