Allowable rates of fluid temperature variations and thermal stress monitoring in pressure elements of supercritical boilers
Authors:
- Jan Taler,
- Dawid Taler,
- Karol Kaczmarski,
- Piotr Dzierwa,
- Marcin Trojan
Abstract
Allowable rates of fluid temperature changes in critical elements of supercritical steam boilers were determined assuming a quasi-steady state of temperature distribution in pressure components. A method was proposed for monitoring the thermal stresses in the critical pressure components.
- Record ID
- CUTb061ba48708d46618846e7e3cff1281d
- Publication categories
- ; ;
- Author
- Pages
- [1-3]
- Other elements of collation
- rys.; wykr.; Oznaczenie streszczenia - Abstr.
- Substantive notes
- Ścieżka dostępu: Session 20 - Heat and Mass Transfer in Nuclear Applications 2, Heat Exchangers, Heat Pipe 3, Mixing Devices and Phenomena/160200.pdf
- Book
- Proceedings of ICCHM2T2017 [10th International Conference on Computational Heat, Mass and Momentum Transfer], May 28-June 1, 2017, Seoul, Korea, 2017, [S.l.], [s.n.], [3] p.
- Keywords in English
- supercritical steam boilers, allowable heating and cooling rates, pressure elements, quasi-steady state, boiler start-up